Fanuc · i Series CNC Hardware
This signal indicates that the third spindle of the Fanuc i Series CNC has detected an abnormal load condition. This implies the spindle motor is operating beyond its normal current limits, which can cause overheating, drive trips, or damage to the motor or mechanical components.
Click steps to track your progress.
Inspect the cutting tool for wear or damage and ensure correct cutting parameters are used.
Check the spindle mechanics for any signs of binding, excessive friction, or damage to bearings.
Monitor spindle motor current and load meter readings during operation from the Fanuc i Series CNC diagnostic display.
Verify spindle drive parameters (e.g., maximum current, acceleration/deceleration times, torque limits) against machine specifications.
Test the spindle motor and power cables for short circuits or ground faults using appropriate electrical testing equipment.