950

PMC System Alarm

Fanuc · Series 20 CNC

What does 950 mean?

This alarm indicates a general system error within the Programmable Machine Controller (PMC) of the Fanuc Series 20 CNC. The PMC handles the machine's ladder logic, I/O, and interlock functions, so an error here means basic machine operations, axis movement, or tool changes may be impossible.

Common Causes

  • Error in the PMC ladder program (e.g., syntax error, invalid logic).
  • Faulty PMC hardware or memory module.
  • Loss of PMC parameters or user data due to battery failure.
  • I/O module malfunction or communication error with I/O devices.
  • Excessive noise on the I/O lines affecting PMC operation.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the PMC diagnostic screen for any specific sub-alarms or error messages related to the PMC.

  2. 2

    Verify the PMC ladder program for recent changes or known issues. If a backup is available, try reloading a known good program.

  3. 3

    Check the PMC battery (if separate from main CNC battery) and replace if low to prevent parameter loss.

  4. 4

    Inspect all I/O modules and their wiring for loose connections, damage, or short circuits.

  5. 5

    Power cycle the CNC system and PMC to clear any transient errors. If the alarm persists, the PMC module may be faulty.