973

NMI Alarm by Unknown Cause

Fanuc · Series 20 CNC

What does 973 mean?

This alarm indicates a Non-Maskable Interrupt (NMI) has occurred within the Fanuc Series 20 CNC, but the system could not specifically identify the source or cause of the NMI. This signifies a severe, unidentifiable hardware or fundamental software issue, leading to a system halt.

Common Causes

  • Transient or intermittent hardware fault not captured by specific NMI handlers.
  • Severe power supply instability or noise affecting multiple components.
  • Corruption of critical system firmware or BIOS.
  • Motherboard or backplane malfunction affecting bus communication.
  • Unforeseen hardware interaction or component failure.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Perform a complete power cycle of the CNC system, including removing main power, to ensure a full reset.

  2. 2

    Verify all power supply units and their output voltages for stability and correct levels. Inspect for ripple.

  3. 3

    Inspect the entire CNC main board, backplane, and all installed modules for any visible damage, loose connections, or signs of overheating.

  4. 4

    Check for any strong sources of electromagnetic interference (EMI) around the CNC cabinet.

  5. 5

    If the alarm persists and no specific cause can be identified, consider a systematic replacement of the main CNC board as it points to a deep-seated hardware fault.

Browse all codes in this manual (43)