PSM Main Circuit Heat Sink Overheat

Fanuc · Series 30i CNC

What does 3 mean?

The alarm indicates that the temperature of the main circuit heat sink within the Power Supply Module (PSM) has risen abnormally. This condition can lead to thermal stress on power components and potential module failure if not addressed. It implies a failure in heat dissipation.

Common Causes

  • Cooling fan for the main circuit is broken or not rotating.
  • Accumulation of dust in the cooling system, obstructing airflow.
  • System overload, causing excessive heat generation.
  • Poor installation of the control printed-circuit board, potentially due to detached connectors between control and power boards.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check whether the cooling fan for the main circuit rotates normally.

  2. 2

    Clean the cooling system, including heat sinks and fan blades, using a vacuum cleaner or factory air blower.

  3. 3

    Examine the operating conditions to identify and mitigate any overload situations.

  4. 4

    Ensure the faceplate (control printed-circuit board) is pushed in completely to secure all connectors.