300

Temperature Sensor Connection Failure

Fronius · Perfect Charging

What does 300 mean?

The battery charger was unable to establish a connection with the temperature sensor. This prevents the charger from monitoring crucial temperature data, which is essential for safety and optimal charging performance.

Common Causes

  • A disconnected or damaged wiring between the charger and the temperature sensor.
  • A faulty temperature sensor that is not responding or providing a valid signal.
  • Incorrect wiring or improper termination of the sensor connection at the charger's input terminals.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the physical connection and wiring integrity of the temperature sensor, ensuring it is securely connected to the designated terminals.

  2. 2

    Measure the resistance of the temperature sensor across its terminals and compare it to the expected resistance values for its ambient temperature.

  3. 3

    Check the sensor's terminal connections on the charger for proper seating and absence of corrosion.