57

Message Time Limit Exceeded (CAN)

Fronius · Perfect Charging

What does 57 mean?

The charger did not receive an expected message from the battery via CAN bus within the allowed time frame. This indicates a delay or loss of communication packets, leading to a timeout and a communication failure.

Common Causes

  • High latency or an intermittent connection on the CAN bus, causing messages to be delayed or dropped.
  • The battery's BMS is slow to respond to queries or experiencing internal processing delays.
  • Incorrect timeout settings configured in the charger's CAN communication parameters, making it too aggressive.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the CAN bus wiring for proper shielding, grounding, and integrity to ensure reliable signal transmission.

  2. 2

    Check the battery's BMS for any internal fault codes or indications of slow operation or processing overload.

  3. 3

    Review the charger's CAN communication timeout parameters and adjust them if necessary to be more tolerant of network latency.