305

No power being fed in, despite closed relay

Fronius · Primo GEN24 Operating Instructions

What does 305 mean?

This code indicates that the inverter's internal relay is closed, but no power is being fed into the grid. This suggests a potential issue in the power path even though the switching element is engaged, causing a short-term interruption before the inverter attempts to restart.

Common Causes

  • Failure or malfunction of internal power stage components despite relay closure.
  • Grid impedance issues preventing power injection.
  • Faulty internal measurement or control circuitry preventing detection of power flow.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    If this status code keeps recurring, contact your system engineer for diagnosis.

  2. 2

    Perform an AC reset by cycling the automatic circuit breaker to potentially clear transient relay issues.

  3. 3

    Verify the AC grid voltage and frequency are within the permissible operating range.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026