EL
ErrorLib
Brands
||
  1. Home
  2. Fronius
  3. Primo GEN24 Operating Instructions
  4. 309
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

309

DC input voltage MPPT 1 too high

Fronius · Primo GEN24 Operating Instructions

What does 309 mean?

This code indicates that the DC input voltage from the PV string connected to Maximum Power Point Tracker 1 (MPPT 1) is too high. This triggers a short-term interruption in energy feeding, and the inverter will attempt to resume its startup routine.

Common Causes

  • PV string connected to MPPT1 has an open-circuit voltage (Voc) that exceeds the inverter's maximum input voltage.
  • Faulty PV modules in the string leading to excessive voltage.
  • Incorrect string configuration or number of modules for MPPT1.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    If the status code is displayed continuously, notify a Fronius-trained service engineer.

  2. 2

    Verify the open-circuit voltage (Voc) of the PV string connected to MPPT1 and ensure it is within the inverter's specified limits.

  3. 3

    Reconfigure or modify the PV string connected to MPPT1 if its voltage exceeds the inverter's rating.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

102AC voltage too high103AC voltage too low105AC frequency too high
Source: Fronius Primo GEN24 Operating Instructions
Open Manual (Page 105)Search more codes in this manual