EL
ErrorLib
Brands
||
  1. Home
  2. Fronius
  3. Primo GEN24 Operating Instructions
  4. 425
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

425

Unable to communicate with the power stage set

Fronius · Primo GEN24 Operating Instructions

What does 425 mean?

This code indicates a loss of communication between the inverter's control system and its power stage set. This prevents proper operation, but the inverter will automatically attempt to re-establish communication and resume feeding energy into the grid.

Common Causes

  • Interference or fault on the internal communication bus between control and power boards.
  • Hardware malfunction of the power stage set or control system communication interfaces.
  • Loose internal cabling connecting these components.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    If the status code is displayed continuously, notify a Fronius-trained service engineer for diagnosis.

  2. 2

    Perform an AC reset by cycling the automatic circuit breaker to restart the inverter's internal communication.

  3. 3

    Check for stable internal power supplies to both the control system and power stage set.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

102AC voltage too high103AC voltage too low105AC frequency too high
Source: Fronius Primo GEN24 Operating Instructions
Open Manual (Page 106)Search more codes in this manual