989

No communication with Fronius Smart Meter

Fronius · Solar Energy

What does 989 mean?

This code indicates a lack of communication between the Fronius Symo Hybrid inverter and the Fronius Smart Meter, resulting in no meter data and inability to perform battery operation. Feed-in to the grid will resume, but battery functionality is impaired.

Common Causes

  • Fronius Smart Meter not receiving power supply
  • Wiring issues between the inverter and the Fronius Smart Meter

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the wiring between the Fronius Symo Hybrid and the Fronius Smart Meter for proper connection and integrity.

  2. 2

    Verify the power supply to the Fronius Smart Meter is active and stable.