104

AC Grid Impedance

Fronius · Symo Advanced

What does 104 mean?

This status code indicates that the AC grid impedance is too high, preventing the Fronius Primo GEN24 208-240 inverter from operating correctly. This can be caused by long or undersized AC cables, or a generally weak utility grid connection.

Common Causes

  • AC cable connecting the inverter to the grid is too long or has an insufficient cross-section, leading to increased impedance.
  • The AC grid itself is too weak or has high internal impedance, making it unsuitable for inverter operation.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the AC grid connection point for loose terminals or poor contact.

  2. 2

    Verify the AC cabling to the inverter terminals (wire gauge and length) and ensure it meets installation guidelines to minimize impedance.

  3. 3

    Observe the stability of the AC grid by monitoring voltage and current under load.

  4. 4

    De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the inverter may require service.