203

Overcurrent

Fronius · Symo Advanced

What does 203 mean?

This status code indicates that an overcurrent condition has been detected on the DC input of the Fronius Primo GEN24 208-240 inverter. This typically suggests a short circuit within the solar module strings or other problems with the PV array, or potentially an internal defect in the inverter.

Common Causes

  • A short circuit in one or more solar module strings connected to the inverter.
  • Mismatch or other configuration issues within the solar module strings leading to excessive current.
  • An internal defect within the inverter's DC input current sensing or protection circuit.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the solar module strings for correct configuration and functionality, looking for potential short circuits or incorrect wiring.

  2. 2

    Measure the DC input current at the inverter's DC input terminals and compare it against the inverter's maximum input current rating.

  3. 3

    Isolate individual strings to identify the source of the overcurrent.

  4. 4

    De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the inverter may require service.

Browse all codes in this manual (41)
Verified technical data. Last updated: April 2026