Fronius · Symo Advanced
This status code indicates that an overcurrent condition has been detected on the DC input of the Fronius Primo GEN24 208-240 inverter. This typically suggests a short circuit within the solar module strings or other problems with the PV array, or potentially an internal defect in the inverter.
Click steps to track your progress.
Check the solar module strings for correct configuration and functionality, looking for potential short circuits or incorrect wiring.
Measure the DC input current at the inverter's DC input terminals and compare it against the inverter's maximum input current rating.
Isolate individual strings to identify the source of the overcurrent.
De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the inverter may require service.