This status code indicates that the insulation resistance of the solar module strings connected to the Fronius Primo GEN24 208-240 inverter is too low. This is a critical safety issue, often caused by moisture ingress or physical damage to the solar modules or DC cabling, compromising electrical isolation.
Click steps to track your progress.
Measure the insulation resistance of the solar module strings between PV+ to ground (GND) and PV- to ground (GND) using a megohmmeter (e.g., at 500VDC). Expect values >1 MΩ.
Inspect all DC cabling for visible signs of damage, cuts, abrasions, or signs of moisture ingress.
Examine solar modules for physical damage to the backsheet, frame, or glass that could compromise insulation.
De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the inverter may require service.