Fronius · Symo Advanced
This status code indicates an asymmetry in the PV input currents, specifically relevant for the Fronius Primo GEN24 208-240 inverter when multiple parallel strings are connected to a single MPPT. This can result from differing string characteristics, partial shading, or issues with individual modules.
Click steps to track your progress.
Check the configuration of all solar module strings for consistent module types, number of modules, and equal string lengths.
Inspect the PV array for partial shading that might be affecting one or more parallel strings.
Measure the DC input currents of each individual string at the inverter's DC input terminals to identify the imbalanced string.
De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the inverter may require service.