EL
ErrorLib
Brands
||
  1. Home
  2. Fronius
  3. Symo Advanced
  4. 301
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

301

Inverter Temperature

Fronius · Symo Advanced

What does 301 mean?

This status code indicates that the internal temperature of the Fronius Primo GEN24 208-240 inverter is too high. This usually occurs due to insufficient cooling, high ambient temperatures, or a malfunction in the inverter's cooling system, leading to a potential derating or shutdown to prevent damage.

Common Causes

  • Blocked or obstructed air vents on the inverter, impeding proper airflow.
  • Ambient temperature at the inverter's installation location is excessively high.
  • Insufficient clearance around the inverter, preventing adequate heat dissipation.
  • A defect in the inverter's internal cooling fan or thermal management system.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the inverter's air vents for any blockages, dust accumulation, or debris and clean them if necessary.

  2. 2

    Measure the ambient temperature at the inverter's location and ensure it is within the specified operating limits.

  3. 3

    Verify that there is sufficient clearance (as per manual specifications) around the inverter to allow for proper airflow and cooling.

  4. 4

    De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the inverter may require service.

Browse all codes in this manual (41)
Verified technical data. Last updated: April 2026

Related Faults

102AC Voltage Range103AC Frequency Range1030WSD Open
Source: Fronius Symo Advanced
Open Manual (Page 149)Search more codes in this manual