This status code indicates that the Wired Shutdown (WSD) input on the Fronius Primo GEN24 208-240 inverter is active, triggering a shutdown command. This can be caused by the WSD button being pressed, a wiring issue in the WSD circuit (e.g., a short circuit), or an external shutdown device being activated.
Click steps to track your progress.
Check the status of the WSD button or any external shutdown device connected to the WSD input; ensure it is in the inactive state.
Inspect the WSD wiring for any signs of short circuits, damage, or improper connections at the inverter terminals.
Verify that the WSD input is deactivated if normal system operation is desired.
De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the inverter may require service.