2195 F150
Motor %.1s: I-n incorrect
Heidenhain · NC Control
What does 2195 F150 mean?
The I-N (rated current) of the motor for the displayed axis is incorrect. This means the configured rated current in the NC control does not match the actual motor's specifications.
Common Causes
- I-N (rated current) parameter for the motor on the displayed axis is incorrectly configured.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the motor's rated current parameter setting (I-N) in the NC control for the specified axis against the motor nameplate data.
- 2
Check the motor power cable connections for proper termination, continuity, and absence of damage.
- 3
Ensure the motor being used is appropriate for the application and that the drive's capabilities are matched to the motor's rated current.
- 4
If an inverter is involved, verify its rated current parameters are correctly set to match the motor's specifications.
Verified technical data. Last updated: March 2026
Related Faults
Source: Heidenhain NC Control