2879 A110

Safe speed SRG exceeded %.2s

Heidenhain · NC Control

What does 2879 A110 mean?

The safe reduced speed (SRG) was exceeded for the specified axis while the protective door was open. This indicates a violation of the defined safe operating speed under reduced safety conditions.

Common Causes

  • Safe reduced speed SRG was exceeded.
  • Protective door was open.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Ensure all protective doors are fully closed and their interlock switches are correctly engaged before operating at speeds above the SRG limit.

  2. 2

    Verify the SRG (Safe Reduced Speed) monitoring parameters in the NC control to ensure they are configured correctly for the machine's safety requirements.

  3. 3

    Inspect the axis encoder feedback system for accurate speed measurement, as erroneous feedback could falsely trigger this fault.

  4. 4

    Check the wiring and functionality of the protective door interlock switches to confirm they are reporting their status reliably.