5645 E012

Error in CC switch-off test

Heidenhain · NC Control

What does 5645 E012 mean?

During a CC switch-off test, the CC switch-off signal '-N0' failed to switch to a low (active) level. This indicates a hardware defect on the controller board.

Common Causes

  • CC switch-off signal: -N0 does not switch to low level.
  • Hardware defective.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Power cycle the NC control to attempt a reset of the safety circuit and signal states, then re-attempt the CC switch-off test.

  2. 2

    Check the wiring and connections related to the -N0 signal path on the controller board for any damage, loose terminals, or corrosion.

  3. 3

    Inspect the controller board for any visible damage, burnt components, or signs of malfunction.

  4. 4

    If available, use a multimeter or oscilloscope to monitor the -N0 signal level during the switch-off test to confirm if it remains high when expected to go low.