Controller unit not suited for FS
Heidenhain · TNC CNC Controllers
What does 231-A005 mean?
This warning indicates that the control unit (CC, UEC, UMC) is not suitable for control systems requiring functional safety (FS), as detected during a check of the safety kernel software SKERN-CC. The currently installed controller unit fulfills safety requirements according to EN 13849 but is not approved for functional safety applications.
Common Causes
- The installed controller unit (CC, UEC, UMC) is not approved for functional safety applications.
- Incorrect controller unit type or version installed for an application requiring functional safety (FS).
- Mismatched hardware configuration with the safety kernel software (SKERN-CC) requirements.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the part number and type of the installed controller unit (CC, UEC, UMC) against the machine's functional safety requirements.
- 2
Replace the affected controller unit (CC, UEC, UMC) with a model explicitly approved for functional safety (FS).
- 3
Consult the machine documentation or Heidenhain technical support to confirm the correct controller unit required for your system's safety integrity level.