13487

USB: TNC does not support device

Heidenhain · NC Control

What does 13487 mean?

A USB device connected to the TNC (Heidenhain NC Control) is not supported. The TNC has specific requirements for connected USB devices, particularly regarding formatting.

Common Causes

  • Connected an unsupported USB device to the TNC.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Disconnect any unsupported USB devices from the TNC.

  2. 2

    Ensure that any USB data media used is formatted either as VFAT (FAT32) or ISO 9660 (for CD-ROMs).

  3. 3

    If a USB hub is connected, ensure it is a supported model; if the message recurs without any device changes, this indicates a potential internal issue.

  4. 4

    If the message appears even when no device has been connected or disconnected, document the situation and specific TNC model for service agency review.