EL
ErrorLib
Brands
||
  1. Home
  2. Heidenhain
  3. NC Control
  4. 2203 F200
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

2203 F200

%.1s motor enc. zn ampl. too small

Heidenhain · NC Control

What does 2203 F200 mean?

The ZN amplitude of the encoder (ERN 1381) for the displayed axis is too small. This indicates a problem with the encoder signal integrity, potentially leading to inaccurate position feedback.

Common Causes

  • ZN amplitude of the encoder (ERN 1381) for the displayed axis is too small.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the motor encoder (ERN 1381) cabling for the specified axis, including shielding and ground connections, for damage, loose contacts, or interference.

  2. 2

    Inspect the encoder itself for signs of physical damage, contamination (e.g., oil, dust), or mounting issues that could affect signal generation.

  3. 3

    Verify the power supply voltage to the encoder is present and stable, within the specified operating range.

  4. 4

    If possible, use an oscilloscope to measure the ZN signal amplitude directly at the encoder output and at the control input to detect signal degradation.

Browse all codes in this manual (58)
Verified technical data. Last updated: April 2026

Related Faults

10590 E004SH1 status test to active10591 E005SH1 status test to inactive10592 E010SH2 status test to active
Source: Heidenhain NC Control
Open Manual (Page 158)Search more codes in this manual