Heidenhain · NC Control
The safe reduced speed (SRG) was exceeded for the specified axis while the protective door was open. This indicates a violation of the defined safe operating speed under reduced safety conditions.
Click steps to track your progress.
Ensure all protective doors are fully closed and their interlock switches are correctly engaged before operating at speeds above the SRG limit.
Verify the SRG (Safe Reduced Speed) monitoring parameters in the NC control to ensure they are configured correctly for the machine's safety requirements.
Inspect the axis encoder feedback system for accurate speed measurement, as erroneous feedback could falsely trigger this fault.
Check the wiring and functionality of the protective door interlock switches to confirm they are reporting their status reliably.