Motor current was detected as non-zero during a cutout channel test (24-hour test). This indicates that current is still flowing to the motor when it should be fully disconnected or de-energized, posing a potential safety risk.
Click steps to track your progress.
Ensure that during the cutout channel test, no motor current is deliberately being commanded by the control or any residual energy is present.
Check the inverter for the specified axis for any internal faults, leakage current, or sticky contacts when it is commanded to be off.
Inspect the motor power cables for any short circuits or ground faults that could cause current flow even when the inverter is disabled.
Verify that the inverter's output stage completely de-energizes the motor during the cutout channel test, preventing any residual voltage or current.