5646 E013

Error in CC switch-off test

Heidenhain · NC Control

What does 5646 E013 mean?

During a CC switch-off test, the CC switch-off signal '-N0' failed to switch to a high (inactive) level. This indicates a hardware defect on the controller board.

Common Causes

  • CC switch-off signal: -N0 does not switch to high level.
  • Hardware defective.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Power cycle the NC control to attempt a reset of the safety circuit and signal states, then re-attempt the CC switch-off test.

  2. 2

    Check the wiring and connections related to the -N0 signal path on the controller board for any damage, loose terminals, or corrosion.

  3. 3

    Inspect the controller board for any visible damage, burnt components, or signs of malfunction.

  4. 4

    If available, use a multimeter or oscilloscope to monitor the -N0 signal level during the switch-off test to confirm if it remains low when expected to go high.

Browse all codes in this manual (58)
Verified technical data. Last updated: April 2026

Related Faults

10590 E004SH1 status test to active10591 E005SH1 status test to inactive10592 E010SH2 status test to active
Source: Heidenhain NC Control
Open Manual (Page 273)Search more codes in this manual