What does 5647 E014 mean?

During a CC switch-off test, the CC switch-off signal '-N0' failed to switch correctly on both CC (Controller Control) units. This suggests a hardware defect or an issue with the connection between the controller boards.

Common Causes

  • CC switch-off signal: -N0 does not switch on both CCs.
  • Hardware defective.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Power cycle the NC control to reset the system and re-attempt the CC switch-off test.

  2. 2

    Check the communication and wiring connections between both controller boards (CCs) for damage, looseness, or improper termination.

  3. 3

    Inspect both controller boards for any visible damage, signs of overheating, or component failures.

  4. 4

    Verify that the -N0 signal path is correctly implemented and functioning across both CC units, confirming signal integrity.

Browse all codes in this manual (58)