The standstill monitoring (SBH) was set to 0, or parameter MP1054.x = 0, or an internal software error occurred. This implies that the safety function for standstill monitoring is incorrectly configured or malfunctioning.
Click steps to track your progress.
Verify the setting of parameter MP1054.x (traverse per motor revolution) for the affected axis; ensure it is not set to 0 if standstill monitoring is active and movement is expected.
Check other safety parameters related to SBH (Safe Controlled Stop or Standstill Monitoring) to ensure they are configured correctly for the application.
Power cycle the NC control to clear any transient internal software errors.
Document the current parameter settings and operating conditions to provide to a service agency if the issue persists.