231-A092

Drive lock through safety software (System test)

Heidenhain · TNC CNC Controllers

What does 231-A092 mean?

This error indicates that a drive has been locked by the safety software because a system test is active. An attempt was made to switch on a drive while the system was still executing a test program, or due to an internal software error.

Common Causes

  • System test is active, preventing normal drive operation.
  • Attempt to switch on a drive while the system is still in a test program.
  • Internal software error.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Ensure that any active system test or diagnostic program has completed its execution and is no longer active.

  2. 2

    Verify the operating mode of the machine to confirm it is not in a test or commissioning mode.

  3. 3

    Check the software version of the controller and update it if a known issue related to test mode management exists.

  4. 4

    Consult the machine's operation manual for the correct procedure to exit a system test and resume normal operation.

Browse all codes in this manual (47)
Verified technical data. Last updated: April 2026

Related Faults

231-A001Cancelation of brake-test call monitoring231-A002Cancelation of brake-line-test call monitoring231-A003SPLC commissioning mode active
Source: Heidenhain TNC CNC Controllers
Open Manual (Page 465)Search more codes in this manual