ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

231-A095

Spindle drive lock, status of permissive button invalid

Heidenhain · TNC CNC Controllers

What does 231-A095 mean?

This error indicates that a spindle drive was locked. This occurs when an attempt was made to switch on a spindle drive while the guard door was open, and the permissive button was either not pressed or was not released beforehand, or due to an internal software error.

Common Causes

  • Attempt to switch on a spindle drive while the guard door was open and the permissive button was not pressed or not let go beforehand.
  • Faulty permissive button or its associated wiring.
  • Internal software error.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Ensure the guard door is closed before attempting to activate the spindle.

  2. 2

    If guard door must be open for a specific operation, ensure the permissive button is pressed and released correctly according to operational procedures.

  3. 3

    Check the wiring and functionality of the permissive button; verify its electrical contacts and signal integrity.

  4. 4

    Verify the software version of the controller and update it if a known issue related to permissive button logic exists.

Browse all codes in this manual (47)
Verified technical data. Last updated: April 2026

Related Faults

231-A001Cancelation of brake-test call monitoring231-A002Cancelation of brake-line-test call monitoring231-A003SPLC commissioning mode active
Source: Heidenhain TNC CNC Controllers