EL
ErrorLib
Brands
||
  1. Home
  2. Heidenhain
  3. TNC CNC Controllers
  4. 231-E003
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

231-E003

PLC module 9169 illegal

Heidenhain · TNC CNC Controllers

What does 231-E003 mean?

This error indicates that PLC module 9169 has been detected in safety-oriented software as illegal, implying a software error. This module is likely not permitted or improperly configured within the safety context of the system.

Common Causes

  • PLC module 9169 in safety-oriented software is identified as illegal.
  • Software error within the safety kernel or PLC program.
  • Incompatibility between the PLC program and the safety-oriented software version.
  • Incorrect or unauthorized PLC module configuration for safety applications.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the PLC program for any references or usages of module 9169 within safety-related functions and remove or reconfigure if inappropriate.

  2. 2

    Verify the software version of the controller and the PLC program; ensure they are compatible and updated to the latest stable release.

  3. 3

    Consult the Heidenhain documentation to confirm if PLC module 9169 is permitted for use in safety-oriented applications with your specific controller.

  4. 4

    If the module is intentionally used, verify its configuration against safety guidelines and ensure it meets all functional safety requirements.

Browse all codes in this manual (47)
Verified technical data. Last updated: April 2026

Related Faults

231-A001Cancelation of brake-test call monitoring231-A002Cancelation of brake-line-test call monitoring231-A003SPLC commissioning mode active
Source: Heidenhain TNC CNC Controllers
Open Manual (Page 520)Search more codes in this manual