This error occurs during the dynamic test of PLC peripheral devices (PL, MB, UEC) in the Heidenhain TNC CNC Controller. It signifies that the expected signal transition from 0 to 1 on the TEST.B output was not detected. This indicates a problem with the wiring of the TEST.B output, a short circuit, or an incorrect firmware version of the peripheral device, preventing proper safety function verification.
Click steps to track your progress.
Check the wiring of the TEST.B output for continuity, correct terminations, and any signs of damage, insulation breakdown, or short circuits.
Verify that the software version of the Heidenhain TNC CNC Controller and the firmware version of the PLC peripheral device are compatible and up-to-date according to Heidenhain documentation.
Perform a software or firmware update on the controller and/or the peripheral device if outdated or incompatible versions are identified.
Isolate the peripheral device if possible and test the TEST.B output's voltage transition using a multimeter; if it remains static, the device may be faulty.
If troubleshooting efforts do not resolve the issue, contact a Heidenhain service agency for further diagnosis or potential replacement of the faulty device.