2011

String Reversed

Huawei · SUN2000 Solar Inverter

What does 2011 mean?

The polarity of a PV string connected to the SUN2000 is reversed. This can cause the inverter to stop generating power and potentially damage internal components if not corrected.

Common Causes

  • The PV string is reversely connected.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check whether the PV string is reversely connected to the SUN2000.

  2. 2

    Wait until the solar irradiance declines at night and the PV string current drops to below 0.5 A.

  3. 3

    Set the DC SWITCH to the OFF position.

  4. 4

    Correct the string polarity.

Browse all codes in this manual (33)