EL
ErrorLib
Brands
||
  1. Home
  2. Indramat
  3. Indradrive
  4. F6029
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

F6029

Positive travel limit exceeded

Indramat · Indradrive

What does F6029 mean?

The motor's actual position has exceeded the configured positive software travel limit. This fault indicates that the axis has moved beyond its allowed maximum position, potentially entering an unsafe area or causing mechanical damage.

Common Causes

  • Overrun due to excessive inertia or inadequate deceleration.
  • Incorrectly configured positive software travel limit parameter.
  • Faulty position feedback (encoder) providing erroneous actual position values.
  • Control program error commanding movement beyond the limit.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the configured positive software travel limit parameter (e.g., S-0-0XXX Pos Limit) in the IndraDrive.

  2. 2

    Check the motor encoder for proper operation, secure mounting, and reliable signal output.

  3. 3

    Review the motion control program for any commands that might cause overtravel.

  4. 4

    Adjust deceleration ramps to ensure the axis stops within the defined limits, accounting for mechanical inertia.

  5. 5

    Perform a homing or referencing procedure to re-establish the correct position reference.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

E-0000Processor exception errorF4001Double MST failure shutdownF4002Double MDT failure shutdown
Source: Indramat Indradrive
Open Manual (Page 8)Search more codes in this manual