F7041

Plausibility error actual position value

Indramat · Indradrive

What does F7041 mean?

The actual position value reported by the encoder or derived by the safety technology is deemed implausible or inconsistent. This often occurs when there's a significant and unexpected discrepancy between redundant position sensors or internal estimations, indicating a potential loss of reliable position feedback.

Common Causes

  • Faulty or noisy encoder signals.
  • Mechanical looseness or slip between the encoder and the motor/load.
  • Damage to the encoder or its cable.
  • Discrepancy between redundant encoder channels if multiple feedbacks are used.
  • Internal calculation error within the drive's safety logic.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect all encoder connections and cabling for security, damage, and proper shielding against EMI.

  2. 2

    Check the mechanical coupling of the encoder to the motor shaft for any play or slip.

  3. 3

    Verify the functionality of the primary and any redundant position encoders, if applicable.

  4. 4

    Review drive parameters related to position feedback and encoder monitoring for correct configuration.

  5. 5

    Perform an encoder self-test or position calibration procedure to re-establish accurate feedback.