Feedback Error
Indramat · dds 2.1 digital servo drive User Manual
What does S-0-0011 Bit 5 mean?
A Class 1 Diagnostic indicating a problem with the motor's position or velocity feedback device connected to the DDS 2.1 drive. This could include issues with the encoder signal, sensor wiring, or the feedback device itself, leading to a loss of control and drive shutdown. The drive decelerates to zero speed and shuts down torque. This condition is reset only after the cause is cleared and the command 'Reset Class 1 Diagnostics' is received via the service channel.
Common Causes
- Disconnected, loose, or damaged encoder/resolver cable or connector.
- Incorrect wiring of the feedback device to the DDS 2.1 drive.
- Faulty or damaged motor encoder/resolver.
- Electrical noise or interference on the feedback signal lines.
- Incorrect feedback parameters configured in the drive, not matching the installed sensor.
- Mechanical damage to the encoder shaft or mounting.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Inspect the feedback cable (encoder/resolver) for continuity, shorts, and proper shielding, especially at connectors (e.g., X3 and X4 if typical for DDS 2.1).
- 2
Verify all feedback wiring connections to the DDS 2.1 drive are secure and correspond to the wiring diagram.
- 3
Check the mechanical integrity of the encoder/resolver, ensuring it is securely mounted and the shaft is not damaged or slipping.
- 4
Review the drive parameters related to the feedback system (e.g., encoder type, resolution, pole count) to ensure they are correctly configured.
- 5
Test the feedback device signals using an oscilloscope or specialized diagnostic tool if available, checking for proper signal levels and integrity.