E248
Interpolation Acceleration Equals Zero
Indramat · ECODRIVE Controller
What does E248 mean?
This warning indicates that the currently effective acceleration value in the position command value is zero. This can occur if a selected positioning block has been parameterized with an acceleration of a=0. Operating with zero acceleration in interpolation modes can lead to unexpected motion profiles or lack of movement.
Common Causes
- The acceleration value in the position command or a selected positioning block is set to 0.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Identify the active positioning block or command value source.
- 2
Enter a sensible acceleration value greater than 0 for the relevant parameter in the positioning block or command.
- 3
Verify that the motion profile configuration ensures a non-zero acceleration for interpolated movements.
Verified technical data. Last updated: March 2026
Related Faults
Source: Indramat ECODRIVE Controller