E2061

Device overload prewarning

Indramat · IndraDrive MPx02

What does E2061 mean?

The IndraDrive MPx02 has detected that its internal thermal load or output current is approaching its maximum permissible limit. This is a prewarning, indicating that continued operation under current conditions could lead to an overload fault, subsequent shutdown, and potential damage to the drive.

Common Causes

  • The motor or driven load is operating near or above its continuous rating.
  • Ambient temperature around the drive is too high, hindering effective cooling.
  • Insufficient cooling for the drive due to blocked fan vents, a dirty heatsink, or a faulty cooling fan.
  • Incorrect motor or application parameters in the drive (e.g., motor thermal time constant) leading to inaccurate thermal modeling.
  • Excessive short-term peak loads that accumulate thermal stress.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Reduce the mechanical load on the motor or adjust the operating cycle to decrease the average current draw of the motor.

  2. 2

    Check the ambient temperature around the IndraDrive MPx02 and ensure it is within the specified operating limits.

  3. 3

    Inspect the cooling fan of the drive for proper operation and ensure the heatsink fins are free from dust and debris.

  4. 4

    Verify that motor parameters, particularly thermal model parameters, are correctly configured in the drive to match the connected motor.

  5. 5

    Consider increasing the drive or motor size if the application consistently runs near overload conditions, or implement external cooling.

Browse all codes in this manual (56)
Verified technical data. Last updated: March 2026

Related Faults