Fatal hardware error
Indramat · IndraDrive MPx02
What does F8000 mean?
"F8000" is a collective diagnostic message for underlying fatal hardware errors within the IndraDrive MPx02, specifically F8060 (Overcurrent in power section) and F8069 (+/-15Volt DC error). This code is typically not displayed directly, as the more specific fault is shown. The occurrence of this error leads to an immediate torque-free shutdown of the drive, making operation impossible.
Common Causes
- Underlying fatal hardware issues such as overcurrent in the power section.
- An error in the internal +/-15VDC power supply (F8069).
- Internal hardware fault within the IndraDrive MPx02 control or power section.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check the drive display for subsequent specific fatal error messages like F8060 or F8069, which provide more direct fault information.
- 2
Use the service channel to read parameters S-0-0390 (Diagnostic message number) and S-0-0095 (Diagnostic message) to identify the precise hardware fault.
- 3
Perform a complete power cycle of the IndraDrive MPx02 by switching off the main supply, waiting for discharge, and then re-applying power.
- 4
If F8060 (Overcurrent) is indicated, inspect the motor, motor cables, and power section for short circuits or ground faults.
- 5
If F8069 (+/-15VDC error) is indicated, this points to an internal drive hardware fault and requires contacting Indramat service.