05

Axis 1 Not Homed

Indramat · ServoDyn D Servo Drive

What does 05 mean?

This error indicates that Axis 1 of the CLM01.3-M has not completed its homing procedure, which is a mandatory step before operating in Automatic mode. The system cannot perform absolute positioning without a defined home reference.

Common Causes

  • Attempting to select Automatic mode for Axis 1 before a successful homing cycle has been performed.
  • Homing procedure for Axis 1 was initiated but not completed successfully due to an interruption or fault.
  • Incorrect configuration of homing parameters (Parameter 08, Homing Setup and Parameter 09, Homing Offset) for Axis 1.
  • Faulty home limit switch or wiring preventing Axis 1 from detecting its home position.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Switch the CLM01.3-M to Manual mode.

  2. 2

    Perform the homing procedure for Axis 1 as described in the manual to establish a home reference.

  3. 3

    Verify that Parameter 08 (Homing Setup) and Parameter 09 (Homing Offset) for Axis 1 are correctly configured per the application's requirements (refer to Chapter 4).

  4. 4

    Inspect the home limit switch for Axis 1, including its wiring and mechanical actuation, to ensure it is functioning correctly.

  5. 5

    Check for any mechanical obstructions or binding that might prevent Axis 1 from reaching its home position during the homing cycle.

Browse all codes in this manual (51)
Verified technical data. Last updated: March 2026

Related Faults

Source: Indramat ServoDyn D Servo Drive