24

Abs. Range 1

Indramat · ServoDyn D Servo Drive

What does 24 mean?

This error occurs if Axis 1 travels beyond the maximum number of turns (revolutions) supported by its absolute encoder. This indicates an overtravel condition relative to the encoder's multi-turn counting capability.

Common Causes

  • Axis 1 mechanically travels beyond the physical multi-turn range that the absolute encoder can track.
  • Encoder Data A1 parameter (P01) is configured incorrectly for the absolute encoder's actual number of turns.
  • Programmed travel limits for Axis 1 (e.g., Parameters 11/12) are set too wide, allowing overtravel.
  • Mechanical binding or issues causing unexpected travel that exceeds the encoder's range.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify that Parameter P01 (Encoder Data A1) for Axis 1 accurately reflects the total number of revolutions of the absolute encoder.

  2. 2

    Adjust the programmed travel limits (e.g., Parameters 11 and 12 for Axis 1) to ensure they are within the absolute encoder's operational range.

  3. 3

    Inspect the mechanical system of Axis 1 for any overtravel, binding, or obstructions that would cause it to exceed the encoder's limits.

  4. 4

    If a discrepancy exists, compare the value stored in Parameter P01 with the information on the absolute encoder's nameplate.

  5. 5

    Review the application's motion profile to ensure that commanded movements for Axis 1 remain within the safe operating range of the absolute encoder.

Browse all codes in this manual (51)
Verified technical data. Last updated: March 2026

Related Faults

Source: Indramat ServoDyn D Servo Drive