53

CAN Communication Fault

Kone · CMXC-022 Frequency Control Upgrade Kit

What does 53 mean?

A fault in the CAN communication has been detected, indicating that the CAN bus is not functioning correctly. This can be due to power issues, incorrect wiring, improper termination resistor settings, or misconfigured CAN-communication parameters.

Common Causes

  • CAN communication not working properly
  • Incorrect CAN-bus wiring or termination resistor settings
  • Incorrect CAN-communication parameters

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Switch off the supply voltage from all devices connected to the CAN bus

  2. 2

    Check the CAN-bus wiring and the termination resistor settings

  3. 3

    Verify the CAN-communication parameters for correctness

Browse all codes in this manual (40)
Verified technical data. Last updated: April 2026