Kone · CMXC-022 Frequency Control Upgrade Kit
A Controlled Common Use (CCU) activation has occurred, meaning another device connected to the CAN bus initiated the stopping of the R&M Materials Handling Frequency Converter system. This indicates an external device commanding a stop via the shared network.
Click steps to track your progress.
Verify the operational status and control logic of other devices connected to the CAN bus to identify which device is initiating the CCU stop command.
Inspect the CAN bus wiring and connections (e.g., termination resistors, shielding) for damage, loose connections, or incorrect configuration.
Verify the frequency converter's communication parameters (e.g., CAN bus address, baud rate, control source selection) are correctly configured according to the system's design documentation.
Check the status of any external safety circuits or control logic (e.g., emergency stops, interlocks) that are configured to issue a stop command via the CAN bus.