02

System Communication Fault

Kone · Elevator Control

What does 02 mean?

A communication error has occurred within the machine's control system, indicating a failure to exchange data between critical components. This fault disables all motion functions.

Common Causes

  • Interruption or failure in communication channels (e.g., CANbus) between critical system components.
  • Damaged wiring or loose connections in the communication network.
  • Failure of a communication module or node.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect all communication cables and their connectors for physical damage, proper seating, and correct termination between the main control unit and critical system components.

  2. 2

    Verify the nominal supply voltage at the power input terminals of all involved communication modules and control cards.

  3. 3

    Check the status and diagnostic LEDs on the main control unit, communication modules, and connected intelligent devices for any fault indications.

  4. 4

    Verify all communication parameters, such as network addresses, baud rates, and protocol settings, within the Kone elevator control software against the system's documented configuration.