Kone · Frequency Inverter
This error indicates that one or more output phases to the motor are either missing entirely or exhibit a significant imbalance, suggesting an issue with the drive's output stage or the motor connection wiring.
Click steps to track your progress.
Disconnect the motor and measure the resistance between each pair of output phase terminals (U-V, V-W, U-W) on the drive; expect balanced readings.
Check all motor cable connections for looseness, damage, or corrosion at both the drive output and motor input ends.
Measure the insulation resistance of the motor windings to ground and phase-to-phase using a megger to detect potential shorts or open circuits.
If safely accessible, verify the output switching of each phase from the drive using an oscilloscope or appropriate measurement tool.