16

Motor Phasing Reversed

Kone · Frequency Inverter

What does 16 mean?

This error indicates that the motor phases are connected in a way that causes the motor to rotate in the opposite direction than commanded, or the drive detects an incorrect phase sequence. This is typically a wiring issue between the drive and the motor.

Common Causes

  • Incorrect connection of the motor phase wires (U, V, W) to the drive output terminals.
  • Drive parameter setting for motor rotation direction is incorrect or mismatched with the application.
  • If an encoder is used, its direction feedback may not correctly correspond to the motor's actual rotation direction.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the physical connection of the motor phase wires (U, V, W) to the drive output terminals against the wiring diagram.

  2. 2

    If the motor is running in the opposite direction, swap any two output phases (e.g., U and V) at the drive's output terminals to reverse the rotation.

  3. 3

    Check and adjust the drive parameter for motor rotation direction, if such a setting is available.

  4. 4

    If an encoder is used, ensure its feedback direction is consistent with the motor's rotation (refer to Error 14 for encoder direction issues).

Browse all codes in this manual (37)
Verified technical data. Last updated: April 2026