This error indicates that slippage due to reversed motor rotation has occurred for more than 0.5 seconds. Specifically, it is recorded if speed feedback from Port A and B on the master control PCB shows values less than -150 mm during upward travel or greater than 150 mm during downward travel, signifying movement in the unintended direction.
Click steps to track your progress.
Verify the motor's power wiring connections to ensure the correct phase sequence and direction of rotation.
Check the connections and functionality of the speed feedback device (encoder) to Ports A and B on the master control PCB.
Inspect the mechanical coupling between the motor and the lift's traction system for any signs of slippage.
Confirm that the motor rotation direction parameter in the drive settings matches the intended physical direction for upward and downward travel.