32

Safety Circuit Breaks off

Kone · Frequency Inverter

What does 32 mean?

This fault indicates that the critical safety circuit of the lift has been interrupted or opened while the lift was in service. This is a protective measure to immediately halt lift operation when a safety condition is violated.

Common Causes

  • Activation of an emergency stop button in the car or on a landing.
  • Opening of car door or landing door interlocks during travel.
  • Activation of a safety limit switch, such as pit stop switch or overtravel limits.
  • Physical break or poor connection in the safety circuit wiring.
  • Malfunction of a safety component (e.g., safety relay, governor switch).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect all emergency stop buttons in the car and on all landings for activation.

  2. 2

    Verify the closed state of all car door and landing door safety interlocks.

  3. 3

    Check the position and state of all safety limit switches (e.g., pit switch, final limits).

  4. 4

    Perform a continuity test on the entire safety circuit chain to identify any open points.

  5. 5

    Examine the safety relays on the master control board for proper operation and contact closure.