ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

5

Fuse Broken Off

Kone · Frequency Inverter

What does 5 mean?

This error indicates that a protective fuse within the drive or its associated power circuit has blown. A blown fuse typically points to an overcurrent condition or a short circuit occurring either upstream or downstream of the fuse.

Common Causes

  • Short circuit in the motor winding or the motor cable.
  • Overcurrent condition caused by motor overload or an internal drive malfunction.
  • Input power supply surge or transient voltage event.
  • Internal component failure within the drive creating a short circuit path.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Identify and replace the blown fuse with one of the exact specified type and rating.

  2. 2

    Before replacing the fuse, measure the insulation resistance of motor windings and cables (phase-to-phase and phase-to-ground) using a megger to detect any short circuits.

  3. 3

    Check for any direct shorts or persistent overcurrent conditions in the load or wiring that could have caused the fuse to blow.

  4. 4

    Verify the input power supply for stable voltage and the absence of damaging surges or transients.

Browse all codes in this manual (37)
Verified technical data. Last updated: April 2026

Related Faults

02The Lock Drops off in Operation (Emergency Stop)03The Up Limit Switch Drops Off04The Down Limit Switch Drops Off
Source: Kone Frequency Inverter
Open Manual (Page 94)Search more codes in this manual