0112

Overlapping of switches 61:U and N too small

Kone · V3F25/18 drive

What does 0112 mean?

The shaft setup for the V3F25/18 drive is not completed. This indicates an issue with the physical positioning or alignment of the vanes or magnets and their corresponding switches, leading to insufficient overlap between switches 61:U and N.

Common Causes

  • Vanes or magnets and switches are not positioned according to the shaft vane diagram.
  • Vanes are not correctly aligned in accordance to the oscillator reader.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check that the vanes or magnets and switches are positioned according to the shaft vane diagram.

  2. 2

    If vanes are present, ensure they are correctly aligned in accordance with the oscillator reader.

  3. 3

    Perform the shaft setup again after vane or magnet/switch adjustment.