0126

Safety relay open

Kone · V3F25/18 drive

What does 0126 mean?

An emergency stop occurs, and the elevator will not start with the V3F25/18 drive. This fault indicates that the safety relay circuit is in an open state, preventing normal operation.

Common Causes

  • Incorrect connection of XSR1 on the HCB board and control panel.
  • Incorrect setting of parameter (6_38).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the connection of XSR1 on the HCB board and on the control panel.

  2. 2

    Check the setting of parameter (6_38).